Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Microvascular Reactivity of Peri-implant Mucosa in Humans: Effect of Abutment Material
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 5
September/October 2021

Pages 761–768


Microvascular Reactivity of Peri-implant Mucosa in Humans: Effect of Abutment Material

Barbara Mikecs, DMD/Eszter Molnár, DMD, PhD/Réka Fazekas, DMD, MD, PhD/János Vág, DMD, PhD


PMID: 34547080
DOI: 10.11607/prd.5343

The morphology and histology of the soft tissue around the implant are different from the periodontal tissue, but the difference in the regulation of blood flow is not known. The aim of the study was to compare the resting blood flow and the vasodilatation capacity of the gingiva between implants and teeth. Twenty-six healthy volunteers with single-tooth implants were involved. The implant-borne crown was retained on either a zirconia or titanium abutment. The vasodilatation capacity of the gingiva was assessed by a postocclusive reactive hyperemia test. Blood flow was measured by a laser speckle contrast imager at the buccal gingiva of the implant-borne crown and an analog natural tooth. No significant differences in baseline gingival blood flow were observed between the different abutments and the teeth in either region. The hyperemia after compression was significantly attenuated at the zirconia abutments in all regions during the entire investigation period (20 minutes) compared to the titanium abutments and the teeth. No differences were observed between titanium abutments and the teeth. The resting microcirculation seems to be the same at implants and teeth. However, the vascular reactivity might be disturbed at the zirconia, but not at the titanium, abutment.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help